Back to all products Gas
Ultrasonic Gas Flow Module — G25
Commercial and industrial sizing — large commercial sites, district plant rooms and industrial intakes. Qmax 40 m³/h.
Technical specifications
Parameter Value
- Measurement rangeQmin 0.25 m³/h · Qt 2.5 m³/h · Qmax 40 m³/h (G25)
- Accuracy classClass 1.5 per EN 14236 · MID Annex IV (MI-002)
- Host interfaceUART · I²C — direct integration into host MCU of meter or AMR module
- PowerUltra-low power; battery-powered, 15-year lithium primary; mains variant available
- Operating temperature-40 °C to +70 °C operating · -40 °C to +85 °C storage
- Data reporting periodConfigurable from 125 ms (fast) to 32 s (low-power), per-channel
- T & P compensationOn-module temperature and pressure measurement with volume-conversion output
- Form factorIndustrial body, flanged DN65 / DN80 connections
Want a sample, datasheet or pilot?
Send us a one-line request — we'll send the full datasheet, pricing for your volume, and arrange a sample if it fits.
Request datasheet