Back to all products Gas
Ultrasonic Gas Flow Module — G10
Light-commercial sizing — small commercial buildings, bakeries, laundries and boiler rooms. Qmax 16 m³/h.
Technical specifications
Parameter Value
- Measurement rangeQmin 0.10 m³/h · Qt 1.0 m³/h · Qmax 16 m³/h (G10)
- Accuracy classClass 1.5 per EN 14236 · MID Annex IV (MI-002)
- Host interfaceUART · I²C — direct integration into host MCU of meter or AMR module
- PowerUltra-low power; battery-powered, 15-year lithium primary; mains variant available
- Operating temperature-40 °C to +70 °C operating · -40 °C to +85 °C storage
- Data reporting periodConfigurable from 125 ms (fast) to 32 s (low-power), per-channel
- T & P compensationOn-module temperature and pressure measurement with volume-conversion output
- Form factorLight-commercial body, G2" threaded / flanged DN50 options
Want a sample, datasheet or pilot?
Send us a one-line request — we'll send the full datasheet, pricing for your volume, and arrange a sample if it fits.
Request datasheet